Learning Center

FAQs

Q

I possum tuum directorium et data sheet?

A

Productum informationem obtinere potes in nostris downloads vel in singulis paginis productis detail

Q

2 Possum prolationem?

A

Scilicet! Exemplar (Partis Numeri) et quantitatis confirma, Si quas speciales exigentias habes, eas nobis enumerare, et te opportune in omnibus requisitis tuis ostendemus;

Q

3 Qualem mercedem accipis? Quid de traditione?

A

Communiter reddere potes per rationem nostram T/T, Sed pro ordine quodam iudicii, qui parvam quantitatem habet, Occidentem Uion et Alipay sustinemus.

Q

IV l potest accipere exemplum? ls quod liberum?

A

Exemplaria in promptu sunt, sed sumptus et feugiat lateri tuo operiri debent.

Q

5 Quales figurae in ZP seriei vacui pads praesto sunt? Item quaenam applicationes differentiae?

A

Vacuum Pad Figurae & Applications:
Plana: Specimen pro planis, vel-exsurrexerunt workpieces.
Costis planis: Idonea ad deformabilia workpieces vel eas quaerunt securam remissionem.
Deep:pro curva workpieces.
Follis: usus cum spatio limitatur ad buffers vel superficiebus inclinatis.
Oval : Optimus pro longis operibus vel illis cum parvis contactibus locis accurata positione indigens.
Coniuncta pila : Pro workpieces cum superficiebus non-horizontalibus.
High Load : Designed for heavy workpieces.
Silicone Purgamentum semiconductivum : electrostatic missionem praebet tutelam (resistentiae humilitatis superficiei).
Quiddam: Pro workpieces sive effusio impulsum vario cum requirat.

Q

6 Quid faciendum est cum pressione vacuum generans in ZH seriei vacuum decrescit?

A

ZH Series (Corpus Ported Type):
1. lf plures unitates communem exhauriunt lineam, gradus vacuos ut expectata debita interference non oriri possunt. Tibia exhauriendi liberaliter amplitudo est ad retrahendam pressuram.
2. Cum silentio utens, materiam acusticam contaminationis inspicite vel ifnecessany suam inspectionem candam.
Series ZH (Box Type):
1. Quin, si materia sana absorbens sordida est ac repone, si requiritur All ZH Series Exemplar:
1. Inspice quaelibet res externas (exempli causa, obstantia, umorem) e vacuo latere ingressu, asthes diffundentem internam obstruere et imminuere. Semper colum colum vacuum in parte anhelitu instituo.
2. Confirma copiam pressionis unitatis stabilis manere nec omissam esse.

Q

7 Quomodo invenio vim poculorum vacui seriei elevatio ZP suctionis?

A

Vis elevatio poculorum vacui suctionis haberi potest ex formula calculi tum ex vi mensa theoretica elevatio.
Formulae calculandi:
W = P x S x 0.1 x 1/t
(W: vis elevatio (N), P: pressionis vacuum (Kpa), S: Area caudex (cm²), et t: factor Salutis 4 vel plurium ad elevationem horizontalem et 8 vel magis ad elevationem verticalem)
Theorica vis mensae elevatio;
Theorica elevatio vis inveniri potest utens pad diametri et pressione vacuum.
Factorem salutis non includit, vim elevandi theoreticam per factorem salutis "t" dividere vim ad levationem obtinendam.
vis elevatio = vis elevatio theoretica t
Vis tabula elevatio theorica (vis elevatio theorica = P x S x 0,1) infra ostenditur.



Theoretical vis elevatio (Theoretical Force elevatio=P×S×0.1)
Codex/Suctionis Cup Diameter(ø1.5 ad ø50) (N)
Codex / Suctionis Cup diametri (mm) 1.5 2 03.5 4 6 8 10 13 16 ø20 25 32 40 50
Codex/Suctionis Cup area S(cm2) 0.02 0.03 0.10 0.13 0.28 0.50 0.79 1.33 2.01 3.14 4.91 8.04 12.6 19.6
Vacuum pressura (kPa) -85 0.15 0.27 0.82 1.07 2.40 4.2 6.6 11 17 26 41 68 106 166
-80 0.14 0.25 0.77 1.00 2.26 4.0 6.2 10 16 25 39 64 100 157
-75 0.13 0.24 0.72 0.94 2.12 3.7 5.8 10 15 23 36 60 94 147
-70 0.12 0.22 0.67 0.88 1.98 3.5 5.5 9.3 14 22 34 56 87 137
-65 0.11 0.20 0.63 0.82 1.84 3.2 5.1 8.6 13 20 31 52 81 127
-60 0.11 0.19 0.58 0.75 1.70 3.0 4.7 8.0 12 18 29 48 75 117
-55 0.10 0.17 0.53 0.69 1.55 2.7 4.3 7.3 11 17 27 44 69 107
-50 0.09 0.16 0.48 0.63 1.41 2.5 3.9 6.7 10 15 24 40 62 98
-45 0.08 0.14 0.43 0.57 1.27 2.2 3.5 6.0 9 14 22 36 56 88
-40 0.07 0.13 0.38 0.50 1.13 2.0 3.1 5.3 8 12 19 32 50 78
Codex/Suctionis Cup Diameter (ø63 ad ø340) (N)
Codex / Suctionis Cup diametri (mm) 63 ø80 100 125 150 200 ø250 ø300 340
Codex/Suctionis Cup area S(cm2) 31.2 50.2 78.5 122.7 176.6 314.0 490.6 706.5 907.5
Vacuum pressura (kPa) -85 265 427 667 1043 1501 2669 4170 6005 7714
-80 250 402 628 982 1413 2512 3925 5652 7260
-75 234 377 589 920 1325 2355 3680 5299 6806
-70 218 351 550 859 1236 2198 3434 4946 6353
-65 203 326 510 798 1148 2041 3189 4592 5899
-60 187 301 471 736 1060 1884 2944 4239 5445
-55 172 276 432 675 971 1727 2698 3886 4991
-50 156 251 393 614 883 1570 2453 3533 4538
-45 140 226 353 552 795 1413 2208 3179 4084
-40 125 201 314 491 706 1256 1962 2826 3630
Oval Pad/Suction Cup (2/4 ad 8x30,30x50) (N)
Codex / Suctionis Cup diametri (mm) 2×4 3.5×7 4x10 5×10 6x10 4x20 5×20 6×20 8x20 4x30 5×30 6×30 8×30 30×50
Codex/Suctionis Cup area S(cm2) 0.07 0.21 0.36 0.44 0.52 0.76 0.94 1.12 1.46 1.16 1.44 1.72 2.26 13.07
Vacuum pressura (kPa) -85 0.60 1.79 3.0 3.7 4.4 6.4 7.9 9.5 12.4 9.8 12.2 14.6 19.2 112
-80 0.56 1.68 2.8 3.5 4.1 6.0 7.5 8.9 11.6 9.2 11.5 13.7 18.0 105
-75 0.53 1.58 2.7 3.3 3.9 5.7 7.0 8.4 10.9 8.7 10.8 12.9 16.9 98
-70 0.49 1.47 2.5 3.0 3.6 5.3 6.5 7.8 10.2 8.1 10.0 12.0 15.8 92
-65 0.46 1.37 2.3 2.8 3.3 4.9 6.1 7.2 9.4 7.5 9.3 11.1 14.6 85
-60 0.42 1.26 2.1 2.6 3.1 4.5 5.6 6.7 8.7 6.9 8.6 10.3 13.5 79
-55 0.39 1.16 1.9 2.4 2.8 4.1 5.1 6.1 8.0 6.3 7.9 9.4 12.4 72
-50 0.35 1.05 1.8 2.2 2.6 3.8 4.7 5.6 7.3 5.8 7.2 8.6 11.3 66
-45 0.32 0.95 1.6 1.9 2.3 3.4 4.2 5.0 6.5 5.2 6.4 7.7 10.1 59
-40 0.28 0.84 1.4 1.7 2.0 3.0 3.7 4.4 5.8 4.6 5.7 6.8 9.0 53