Products
Mark-free Vacuum Suctionis Cucurbitulae ZP2
  • Mark-free Vacuum Suctionis Cucurbitulae ZP2Mark-free Vacuum Suctionis Cucurbitulae ZP2
  • Mark-free Vacuum Suctionis Cucurbitulae ZP2Mark-free Vacuum Suctionis Cucurbitulae ZP2
  • Mark-free Vacuum Suctionis Cucurbitulae ZP2Mark-free Vacuum Suctionis Cucurbitulae ZP2
  • Mark-free Vacuum Suctionis Cucurbitulae ZP2Mark-free Vacuum Suctionis Cucurbitulae ZP2
  • Mark-free Vacuum Suctionis Cucurbitulae ZP2Mark-free Vacuum Suctionis Cucurbitulae ZP2

Mark-free Vacuum Suctionis Cucurbitulae ZP2

Pro fabrica prima Sinarum, officina nostra offert Customised Mark-liberum cucurbitulae Vacuum suctionis ZP2 cum attachiationibus PEEK. Commaelec solutionis directae (Ø6-32mm) prohibet in tabulas solares, lagana et OLEDs scalpere. Aliquam virgas humiles quiddam, est specimen medicinae et electronicarum.
Click et Satus Electio
Redi ad Product Information

Mark-free Vacuum Suctionis Cucurbitulae ZP2

Mark Free Vacuum Suction Cups Zp2

ZP2 Series Gravis officiorum Pad Unit

Descriptio
Quam ad Ordinem
Formularium / Material
Applications
Resource

Professional Sinarum Mark-liberum Vacuum Suction Cucurbitulae ZP2 opificem ac elit, nobis praebent clientes cum comprehensive project administratione muneris.

Series ZP mugit genus calicis vacui cum attachiamento PEEK destinatur: 1) Photovoltaica potentia stationis institutionis (uti cucurbitula vacuum ad tabulas solares transportandas et ne superficies vitrea exasperat); 2) laganum semiconductor (silicon) tractatio, lens optica (vitrum/resin) conventus, electronic ostentatio (OLED/LCD) translatio, et praecisio medicinae fabricam componentem (exampla instrumenti chirurgici accessiones) tractatio.

Mark-liberum Vacuum Suctionis Cucurbitulae ZP2, cum diametris ab 6mm ad 32mm vndique, compacta et specialiter ad industriam electronicarum destinata sunt. Constructum in quiddam telescopio virga minimam pulverem gignit, eamque apprime aptam ad electronicas, medicas, et industrias pharmaceuticae. Suas officinas cum magna copia productorum stirpis, globulus, silicone et materias speciales quales anti-staticas facit.


Key Features ZP2 Mark-liberum Series

Reducitur Vestigium

Mark-liberum Vacuum Suctionis Cucurbitulae ZP2 utetur specialibus rebus non notatis et consilio labii lenis ad residua superficiem et fuluum extenuandum

Apta fabricas sensitivas, ut vitrum, metallum, electronicum

Stabilis suctus dum protegens productum species et defectum rates in productione

Genera materia

Silicone (gradu non-notatum);mundus, summus temperatus resistentia, apta subtilitatis industries

Polyurethane (PU):humilis repugnans lapsum crebris usui residuum

Aliae nativus compositorum non-notatarum praesto ex Commaelec secundum necessitates applicationis

Commaelec obtinet qualitatem materiae consistentem per productionem moderatam transnavigans et in domo

Codex Profiles

Genus plana:nam lenis, plana superficies ad maxime contactum area

Flat with ribs:improves signantes adhuc reducendo notati periculo

Genus follis:leviter aptat superficiebus inaequalibus et praebet cushioning

Plures profile optiones patitur flexibile adaptare ad realem operationem conditionibus


FAQ

Quomodo signum technologiae liberae operatur?

Mark-liberum Vacuum Suctionis Cucurbitulae ZP2 utuntur specialiter formatis elastomoribus non notati et geometriae labrum optimized.
Levis contactus superficies minuit frictionem et pressura puncta
Etiam vacuum distributio notas accentus locales vitat
Tersus materiae oleum ne residuum aut color translationem
Hoc validum suctum efficit, dum superficies sensitivas protegit.


Quae sunt genera ZP2 Mark-liberum pads?

Genus plana: optimum pro superficiebus levibus, rigidis cum area maxime contactus
Plana cum costis: improves signationem cum adhuc notati obscuratis
Genus follis: aptat ad exiguum altitudinis differentias et superficies inaequales
Commaelec plures structuras praebet ut condiciones productionis realis par.


What are the size options for ZP2 pads?

Diametros Latin comprehendunt: φ40, φ50, φ63, φ80, φ100, φ125
Magnitudines parvae: subtilitas partes et onera levia
Magnae magnitudinis: tenaci melius pro maior tabulata
Commaelec molem generis sustinet et magnitudinum nativus ad applicationes specificas.


Quomodo vetas immaturam vestem?

Lego materiam rectam secundum caliditatem et environment
Nimia vacuum pressura aut misalignment
Uti buffering jactu aggeris ad redigendum impulsum in contactu
Iusto inspectione et opportune reponenda labra
Commaelec's summus qualitas materiae (exempli causa, PU, ​​silicone) auxilium praebens servitium vitae in summo cyclo usu.


Quae sunt materiae praesto?

Marc-liber Vacuum Suctionis Cucurbitulae ZP2 praesto sunt in:
Silicone non notati: mundus, calor repugnans, specimen electronicarum
Polyurethane (PU): durabile et obsistens
Nativus componit: anti-static vel applicationes Utilia materiae
Commaelec stabilitatem materiae praestat et per fabricam moderatam constantem observantiam.


Quam ad Ordinem

Mark Free Vacuum Suction Cups Zp2

  • Nullae notae adsorptionis (stricturae constituentes) in workpiece relinquuntur.
    Contactum directum inter fabricam et iuvamentum vitat, insertis ad follem codex ad affectum PEEK ne translationem globulorum constitutorum.
  • Specimen pro seriebus ZP codex follis (6 ad 32)

Mark Free Vacuum Suction Cups Zp2

Pad diameter (mm)
Symbolum Locum codex
06 ZP06B
08 ZP08B
10 ZP10B
13 ZP13B
16 ZP16B
20 ZP20B
25 ZP25B
32 ZP32B
Attachment materia
P PEEK
GP Conductive PEEK

Mark Free Vacuum Suction Cups Zp2

  • Cum codex ordinans, pone "*", infra partem numeri codicis ut infra ostendetur. Nota quod codex non est traditus cum adiunctis coadunatis.
  • Cum affectio conductivorum PEEK facta est, materia conductiva pro caudex utere.
  • Emundare productum ante per affectum.
  • Hoc productum post machining purgari non est. Si productum condicione adhibitum sit in quo portatur, materia residua remanere potest in fragmentis operis. Tersus ante Varro.
  • Si contactus cum materia dura quaestio est, hoc opus non uteris.

Codex Materialis et Characteribus

: Parum vel non influence: Potest esse fretus conditionibus X: Non convenientem

Materia
Characteres
Symbolum Durometer
HS (±5°)
Color
of*
rubber
Operans
temperatus
range (°C)
Oleum
resistentia
gasoline
Oleum
resistentia
benzol
Base
resistentia
Acidum
resistentia
Weatherability Oxone
resistentia
Abrasion
resistentia
IMPERVIUS Solvendo
resistentia
(Benzene, toluene)
Applicationem
NBR N 50 Niger 0 ~ 120 X X X X Translatio operis generalis, tabulam corrugatam, laminam ferream, laminam ferream et cetera
Silicone rubber S 45 ~ 50 White -30 ~ 200 X X X X X Semiconductor, remotionem a jactu moriendi, opus tenue, processus cibi
Urethane rubber U 50~ 60 Brown 0 ~ 60 X X X X X Corrugata tabula, lamina ferrea, lamella Veneer
FKM F 60 Niger 0 ~ 250 X Opus chemicum
Conductive NBR GN 50 ~ 65 0 ~ 100 X X X X Opus generale semiconductoris (Resistentiae electricitatis Static)
Silicone rubbe GS 50~ 60 -10 ~ 200 X X X X X Semiconductor (electricity Static)

Mensa superior tantum notas generales de re cum rubber materialium tegit. Blue symbol is customized models.


Adumbratio applicationis partium pneumaticorum (poculi vacui suctionis) in variis campis industrialibus

I. Caput vires

Vacuum suctus nucleus solutio est "captiva flexilis" in automatione industriae cum quattuor nucleis commoda: comprehensio non damnosa, aptabilitas ad officinas multi-materia/irregularis, munda et environmental tutela, ac flexibilis operatio. Accommodari potest ad varias industrias notas of officinarum (graciles/crass, exquisitas/crassas, sanitate/vexillas).

II. Extraction applicationes per industriam
A. Medicina et industria medici

A.1: Core requisita:Munda et libera pollutio (FDA/GMP obsequentia), mansueta et non damnosa, et praeventionis crux-contaminatio.

A.2 Key missiones:

1. Pharmaceutical packaging: utrem medicamento / lamella pharmaceutica / infusio RAPINA sacculi (cibi gradus siliconis poculi suctionis, nulla particula fundens)

2. Medicinae fabrica conventus: instrumenta chirurgica / catheters medical / fragmenta prosthesis pertractatio (opportuna negativa pressura, deformatio tutelae)

3. Laboratorium biologicum: petri catino / tubum centrifuge / reagens card translationem (repugnans chemica, compatible sterilis)

B. Electronics et semiconductor industriae

B. 1 Caput requisita:anti-static (10⁶-10¹¹Ω), praecisio positionis (errore ≤0.01mm), scabere resistentia

B. 2 Key missiones:

1. Chip/Semiconductor: laganum pertractatio, chip packaging (ceramic/anti-static silicone poculum suctionis, pressionis negativae uniformis ne rupturam)

2. PCB/Componentes: Flexibile PCB, partium microform (resistentium 0402) superficies conseptatae (tenues siliconis/gel/microtae suctionis poculorum ne rugae/discerpendae)

3. Exhibe: tabula LCD/OLED, tange iaculis vitreum (materia alta perspicua, maculas nullas et exasperat)

C. Automobile et autocinetum partium industriam

C. 1 Core requisita:magna suctio (orbis unius suctionis ≥500N), accommodatio multi-specificationis (metal/plastic/vitri), non-lapsi

C.2 Clavis missionum:

4. Corpus fabricandi: lamina ferrea / ostium artus tractatio welding (magna diameter rubber / multi-suctus calicis instructus, textura anti-lapsi)

5. Vitrum / Interior: Windscreen installation, pellicea sedis superficies translatio (temperatus resistens silicone / spongiae suctus calicum, deformationis munimentum)

6. Partes: corpus cylindricum engine / gearbox habitationi iaculis (cincinno vacuo + mechanica, anti-lapso)

D. Cibum et industriam packaging

D.1 Caput postulatum:Cibus gradus materiales (FDA certified), facile ad mundandum, opprimendum renitentem

D.2 Clavis missionum:

1. Cibum tractatio: bona cocta / caro recens / fructus sorting

2. Packaging automation: packaging pera foramen, lobortis sterilis corona (statim eliminationem / multi-punctum suctionis, ad tenues / difficile packaging apta)

E. Logistics and warehoousing industry

R.1 Caput requisita:aptatio efficientis (multa species bonorum), pressio stabilis, anti-lapsio

R.2 Key missiones:

1. Caxton tractantem: e-commerce lobortis sorting (adjustable suctionis ordinata, pressura vacuum)

2. Tabula / roll: Lignum tabula / plastic film translatio volumen (longum habena/poculum annulale suctus, adsorption uniformis ne offset)

F. Nova energia et industriae speciales

F. 1 Nova industria (lithium altilium/pv);

1. Lithium bracteae altilium (poculum anti-staticum porosum suctionis, pulvis anti-pulvis), vitrum photovoltaicum (suctionis siliconis magnae suctionis calicis, sine scabere)

F. 2 Typographia et charta

1. Paper / re captae typis (papyrus materia absorbens, pressus negativus levis ne contagione lacerat et atramentum)

III. De core adaptationis logicae Summarium
Workpiece characteres Pipette adaptatio programma Industriam missiones correspondentes
Tenuis / fragilis / Precision Silicone/terrae ceramicae, pressio negativa micro, micro suctus COLLUM Electronic semiconductores, pharmaceuticals
Gravis items / magna magnitudine Purgamentum materia, magna diametri poculum suctionis, multi-suctio calicis ordinata Autocineta, tabulae logistics
Salutem / praeventionis pollutio Cibus/medicinae silicone gradus, facile ad structuram mundandam Medicina, cibus
Mollis / superficies irregulares Materia spongia, calix deformabilis suctus Car interiora, cibus
Antistatic requisita Silicone antistatic, ion ventus adiuvatur electronic semi-ductor


📄
Institutionem Manual
PDF Download
📊
Admonitio +Cautio Read ante usus)
PDF Download
Hot Tags: Mark-free Vacuum Suctionis Cucurbitulae ZP2, China, Manufacturer, Supplier, Factory
Mitte Inquisitionem
Contactus info
Percontationes de poculis vacui suctionis, generantibus vacuum, accessoriis pneuma- maticis vel indice pretioso, quaeso nobis electronicam tuam relinque et intra 24 horas erimus continuaturi.
X
Crusulis utimur ut meliorem experientiam pasco tibi praebeamus, situm negotiationis et personalize contentus analyse. Hoc situ utendo, ad nostrum crustulorum usum consentis. Privacy Policy
Reject Accipe